3.1.1

See Elevator Control Board Manual 2348-065 for more info. With 1 8 AWG wire. With 16 AWG wire. Issued by DoorKing 8-3000 Memory 2-Card w/Anti-Pass Back Master Code. Programming Names - 1835, 1837 Systems Only Deleting Individual Phone Numbers Delete Names - 1835, 1837 Systems Only. View and Download DKS 1837 Series installation & owner's manual online. 1837/1835/1833 Series PC Programmable Telephone Entry and Access Control Systems. 1837 Series Intercom System pdf manual download. Also for: 1833 series, 1835 series, 1837-089, 1835-089, 1835-084, 1835-080.

Entry Panel Setup (Fig 10)

1. Enter the four-digit MASTER CODE in the field

provided. The master code entered here must
match the four-digit master code that has been
programmed into the entry panel
.

2. Select the SYSTEM MEMORY. The system

memory must match the memory size of the
chips installed in the entry panel
.

3. Set the system TALK TIME.

4. Set the DIRECTORY CODE DIGITS.

5. Check ANTI-PASS BACK for 1833, 1835, 1837 and

1838 (APB is standard in these systems). Un-
check this box if you are programming an 1834 (APB is unavailable in the 1834).

Figure 10

Software Presentasi GerejaChurch Presentation SoftwareWeWorship 2017 Versi 2.7.8 Alternatif EasyworshipPresentasi Gereja untuk menampilkan Text atau Lirik dengan background Gambar atau Video Seperti Easyworship atau Open Song.Cocok di gunakan untuk kegiatan2 ibadah.- 1 Key aktivasi untuk satu komputer seumur hidup(Donasi atau Beli)- Tidak perlu Aktivasi setiap tahun- Gratis Untuk Setiap Update Terbaru bagi yang sudah pernah aktivasi- Lagu termasuk: Kidung Jemaat, Nyanyian Rohani Methodis, Buku Ende, Mandrin Indonesia. Easyworship 2009 serial number free.

3.1.2

Communication Setup (Fig 11)

1. Select Modem, RS-232, DK IM Server or Network

1

from the pull-down menu (The diagnostics option is
used only when you are talking with a DKS
technician on the telephone)
.

Note 1: Requires installation of TCP/IP kit on the
system (P/N 1830-175).

2. If Modem or DK IM Server was selected, enter the

SYSTEM PHONE number in the field provided.
Include the area code if 10-digit dialing is required in your area. When using the DK IM Server,
you MUST include 1+Area Code+ Phone Number
.

Figure 11

3. If

Network

was selected, you will need to enter the static, dynamic or local IP address and the port

number (separated by a colon) in the System IP Address field.

Example: hostname.dyndns.org:1040

Example:

192.168.1.40:1040

Doorking 1835 Installation Manual

4. Select either the 1834 model, or the 1833, 1835, 1837, 1838 models.

5. Select either 10 or 255 Area Codes. The number of area codes selected here must match how

the entry panel area code option was programmed; either 10 area codes or 255 area codes.
255 area codes are only available on REV E or higher circuit boards.

6. If the entry system is set-up on a PBX or KSU and it needs to dial a “9” to get a dial-tone, enter the

number where indicated.

3.1.3

Tone Open Numbers (Fig 12)

Tone open numbers are the numbers that the entry panel will respond to and will cause the programmed relay
action that the tone number was set for. Tone open numbers can be set to activate a single relay or any
combination of relays. Each relay has four tone open number fields that can be set, however when a call is made
to a resident, the resident can only momentarily activate the relay - the system will not respond to other tone
open numbers from a resident.

The other three tone open number fields (Hold, Release, Hold 1 Hr.) are functions designed for the system
administrator and will cause the relay(s) in the entry panel to respond to the programmed command. To use
these functions, the system administrator calls the entry panel via a touch-tone telephone, and then enters a
series of numbers to cause the desired relay action (Refer to the Owner's Manual that came with the entry panel
for instructions on using this feature).

NOTE: The 1834 and 1838 Entry Panels do not have RELAY 0 capability. Leave all Relay 0 fields blank if
programming an 1834 or 1838 entry panel.

1835-066-N-7-13

Page

25

Advertising
Popular Brands
Popular manuals
Advertising

1835-065-E-7-13

29

No factory setting

0 (10 area codes)

0 (OFF)

007 (7 sec)

1 (tone ON)

0 (9600 Baud)

0 (activates relay)

1 (Turned ON)

Single system

Master Code
Number of Area Codes Allowed
Call-Up Operation, Interfacing with DKS 1816 or 1820 Systems Only
Resident Elevator Button Relay Time
Open Tone ON or OFF
RS-232 Speed Setting
Switch Input Feature
Elevator Control Feature
Single or Multiple Systems

Section 3.2 Setup Entry System for PC Programming

3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
3.2.6
3.2.7
3.2.8
3.2.9

26
27
27
27
27
28
28
28
28

* 6 0
* 78
* 36
* 15
* 85
* 18
* 75
* 04

Page #

Factory Setting

Overview for System Keypad Programming

Section

Command

Master

Switch ON

No factory setting

Factory message
Factory message
Factory message
Factory message

Doorking 1835 Programming Manual Download

Programming Letters and Numbers from Keypad
Programming the User Message - 1834, 1835 Systems
Programming the Instruction Message - 1834, 1835 Systems
Programming the User Message - 1837 Systems
Programming the Instruction Message - 1837 Systems

Section 3.4 Programming Letters, Numbers and Messages

3.4.1
3.4.2
3.4.3
3.4.4
3.4.5

33
34
35
36
37

None

* 80
* 81
* 80
* 81

No factory setting
No factory setting
No factory setting
No factory setting

Programming Five-Digit Device Codes
Delete Device Codes
Enabling Facility Codes
Programming Facility Codes

Section 3.6 Programming Device Codes - 1833, 1835, 1837 Only

3.6.1
3.6.2
3.6.3
3.6.4

43
43
43
43

* 70
* 71
* 72
* 73 Epson tx121 driver.

No factory setting
No factory setting
No factory setting
No factory setting

Programming the Anti-Pass Back Mode
Re-Sync All Devices
Re-Sync Individual Devices
Reset Facility Counter

Section 3.8 Anti-Pass Back

3.8.1
3.8.2
3.8.3
3.8.4

45
45
45
45

* 43
* 45
* 46
* 48

No factory setting
No factory setting
No factory setting

Programming Five-Digit Device Codes
Delete Device Codes
Enabling Facility Codes

Section 3.7 Programming Four-Digit Entry Codes

3.7.1
3.7.2
3.7.3

44
44
44

* 02
* 02
* 12

Three (3) digits

No factory setting
No factory setting
No factory setting
No factory setting
No factory setting
No factory setting
No factory setting

No Factory setting

No factory setting

1 (Pause ON)

Programming the Directory Code Length
Programming Directory Code AND 7-Digit Phone Numbers - No Area Code
Programming Area Codes
Programming Phone Numbers that need Area Codes
Programming Names - 1834, 1835, 1837 Systems Only
Deleting Individual Phone Numbers
Delete Names - 1834, 1835, 1837 Systems Only
Delete Area Codes
Display Phone Numbers - 1834, 1835, 1837 Systems Only
PBX Line Access Code Programming
Touch-Tone Dialing Pause

Section 3.5 Programming Phone Numbers and Names

3.5.1
3.5.2
3.5.3
3.5.4
3.5.5
3.5.6
3.5.7
3.5.8
3.5.9
3.5.10
3.5.11

39
39
40
40
41
41
41
42
42
42
42

* 20
* 01
* 24
* 41
* 66
* 01
* 65
* 24
* 06
* 09
* 27

060 (60 sec)

010 (relay 1 activates)

Doorking 1835 Programming Manual Instructions

Touch-tone

010 (relay 1 activates)

Relay Strike Time
Talk Time

Tone Open Numbers

Switch Input Relay(s) Activation
Touch-tone / Rotary-dial
Rotary Dial-9 Relay(s) Activation

Section 3.3 General Programming using System Keypad

3.3.1
3.3.2

3.3.3

30
30

31

Relay 0: 01 (1 sec)
Relay 1: 01 (1 sec)
Relay 2: 01 (1 sec)

Relay 0: # # # #
Relay 1: 9 8 7 6
Relay 2: 5 4 3 2

* 03
* 08

Doorking 1810 Manual

* 05

3.3.4
3.3.5
3.3.6

31
32
32

* 50
* 07
* 51

Doorking 1835 Programming Manual Transmission

Advertising
This manual is related to the following products:

Doorking 1835 Programming Manual Diagram

1834 PC Programmable, 1835 PC Programmable, 1837 PC Programmable

Popular Brands

Doorking 1835 Installation Manual Pdf

Popular manuals